Mountain High EDS O2D1 or O2D2 Pulse Demand Kit

General Description

Mountain High EDS O2D1 or O2D2 Pulse Demand Kit - The patented MH Pulse-Demand™ Electronic Delivery System (EDS) is designed to deliver aviation oxygen in the most efficient and convenient manner possible. With its user-selectable settings, apnea alarm and small size, the EDS is the most flexible portable digital electronic oxygen delivery system in the world.

Two EDS models fit most common needs for a portable oxygen system. The flagship EDS O2D2 device provides oxygen for either one or two users in a single compact unit, while the EDS O2D1 is the single-user “little brother” of the O2D2. The primary difference between the two models is the second-user capability of the O2D2, but otherwise the performance, features, operation and limitations of the O2D1 and O2D2 are essentially identical. This manual describes both models in generic terms, only referring to the O2D1 or O2D2 models when a notable difference exists.
For example …

O2D2: When the O2D2 is used in single-place mode it has basically the same oxygen consumption and battery duration as the O2D1. Since oxygen consumption and battery duration information in this manual is presented on a “per person” basis, this means that when the O2D2 is used with 2 people oxygen consumption will be roughly double, and battery duration roughly half the indicated values.

O2D2: The O2D2 has 2 unique features distinct from the O2D1 which are the option for external power input and audio output. The EDS unit supplies the oxygen you need to stay alert and comfortable while flying by providing a measured pulse of oxygen at the beginning of each inhalation. In contrast to constant flow systems that deliver more oxygen than the body needs, the MH EDS provides oxygen only when you inhale. This patented delivery technology ensures that you stay safe and comfortable by delivering the proper amount of oxygen based on your pressure altitude and breathing rate. The efficiency of this method provides a dramatic increase in cylinder duration, which enables you to enjoy the benefits of oxygen use below the mandated altitude. This means fewer headaches, less fatigue and increased alertness when flying at night or for long distances. It also enables you to save weight and space with a smaller cylinder, and fly longer between refills!

Unlike constant-flow oxygen systems, the MH EDS features “set and forget” operation and can be set to begin providing oxygen either immediately, or above a specified altitude. Oxygen flow is automatically adjusted according to your pressure altitude. When you’re flying, you have more important things to do than adjust your oxygen flow during altitude changes.

The EDS-O2D1-2G System enables the general aviation pilot to fly at pressure altitudes up to 25,000 feet with safety and comfort.  The EDS-O2D1-2G digital Pulse-Demand™ system reduces Oxygen consumption dramatically.  Different from the “standard” constant flow systems, the EDS-O2D1-2G Pulse-Demand™ system wastes no Oxygen during the breathing cycle when oxygen is not being delivered to the lungs.  The average user will enjoy a duration increase of two to three times compared to the constant flow systems.

The built-in Barometer adjusts for Altitude increase while reducing the pilot workload.

Abandoned unit auto shut off:  If you should forget to turn your EDS off after use, it will now go into auto shut-down (drawing very little power) after 3 hours of detecting no use in an attempt to save the batteries for another flight.

Mountain High Pulse Demand Kit price varies depending on selection above.

O2D1 Technical Data

The EDS-O2D1-2G should be used with any of our XCR, XCP, or 4-place FPR regulator. for correct pressure and oxygen delivery. The low-pressure service line is a high quality polyurethane line that is kink-resistant and flexible under varying temperatures. The cannula, face mask and service line connect to the EDS unit via color-coded “Quick-Connects” providing an air-tight fitting by hand. These fittings can be connected and disconnected many times. With the optional XCP connecting kit, the EDS can be used with an XCP system at the same time flow meters are being used. In addition, the optional ALPS Facemask with or without microphone, is the perfect addition to any EDS system.

Width (Widest Point) 3.1″ (79 mm)
Height (With Connectors) 5.23″ (130 mm)
Depth (Front to Rear) 0.95″ (24 mm)
Weight (With Batteries) 7.5 oz. (213 g)
Battery Type 1.5 Volt AA Alkaline (2 Ea.)
Battery Voltage  
NOM ~2.875 VDC
Low Battery – 1 Level ~2.40 VDC ± 0.04 VDC
Low Battery – 2 Level ~2.25 VDC ± 0.04 VDC
MIN Start–Up Voltage ~2.00 VDC ± 0.04 VDC
Battery Current  
Average ~3.25 ma
Peak (~500 ms Max.) ~100 ma
Battery Life  
NOM
(Fresh Batteries, Normal Operating Conditions)
~100 Hrs.
Low Battery – 1 Alert
(Time Remaining at Onset)
~8 Hours
Low Battery – 2 Alarm
(Time Remaining at Onset)
~2 Hours
Test Conditions 25° C, ~25% RH

O2D2 Technical Data

The MH EDS O2D2-2G Kit Pulse Demand Oxygen Delivery System is the only single unit, portable, two-place oxygen system currently available for general aviation. A variety of options allow you, the pilot, to customize a system to your specific needs. The O2D2-2G kit comes complete with (3) AA batteries, 2 standard cannulas, 2 flare tip cannulas, 2 face masks, owners manual, and carry bags.

Note: Our EDS O2D2-2G and O2D1-2G are portable systems designed and calibrated to be used with our regulators (~15 psig. dynamic to 25 MAX. psig. static). However, if you wish to operate from the outlets of a built-in system, we offer the EDS-Inline stabilizing regulator. This will allow our portable EDS systems to operate with built-in systems that supply up to 90 psig. to the outlets in the aircraft.

 Width (Widest Point) 4.3” [109 mm]
Height (With Connectors) 3.85” [98 mm]
Depth (Front to Rear) 1.25” [32 mm] 
Weight (With Batteries) 12.1 oz [343 g]
Battery Type 1.5 Volt AA alkaline (3 ea.)
Battery Voltage  
NOM ~ 4.25 VDC
Low Battery – 1 Level ~ 3.3 VDC ± 0.1 VDC
Low Battery – 2 Level ~ 3.0 VDC ± 0.1 VDC
MIN Start–Up Voltage ~ 2.8 VDC ± 0.1 VDC
Battery Current  
Average ~3.75 mA
Peak (~500 ms Max.) ~220 mA
Battery Life 2 people 1 person
NOM
(Fresh Batteries, Normal Operating Conditions)
~ 50 Hrs ~ 100 Hrs
Low Battery – 1 Alert
(Time Remaining at Onset)
~ 4 Hours ~ 8 Hours
Low Battery – 2 Alarm
(Time Remaining at Onset)
~ 1 Hours ~ 2 Hours
Test Conditions 25° C, ~25% RH
Iten

O2D2

Qty

O2D1

Qty

(a) EDS User Manual 1 1
(b) EDS unit O2D2 O2D1
(c) AA Batteries 3 2
(d) 3M Dual-Lock 2 2
e) Anti-Bacterial
Facemask Wipes
(f) Oxygen Inlet Tube 1 1
(g) EDS Facemask 2 1
(h) Cannula, Standard 2 1
(i) Cannula, Flare-tip 2 1
(j) Tote-bag 2 1
(k) Warranty
Registration Card 
1 1

What is Air?
The air surrounding us is a mixture of gases consisting of 78% nitrogen and 21% oxygen. The remaining 1% is made up of argon, carbon dioxide, and traces of rare gases.

What is Oxygen?
Under normal conditions, pure oxygen is a colorless, tasteless, odorless, non-combustible gas. It is the most important single element in our universe.

Why is Oxygen So Important?
Although it will not burn alone, oxygen supports combustion; in fact, without oxygen there can be no fire. Oxygen, therefore, is not only necessary for the burning of combustible materials, but it is also absolutely essential to support the process of “vital combustion” which maintains human life. Although a person can live for weeks without food or for days without water, he or she dies in minutes if deprived of oxygen. The human body is essentially a converter which consumes fuel and produces heat and energy. It is like a furnace which utilizes the oxygen in the air to burn coal, thus producing heat and power. The human body must have oxygen to convert fuel (the carbohydrates, fats, and proteins in our diet) into heat, energy, and life. The conversion of body fuels into life is similar to the process of combustion; fuel and oxygen are consumed, while heat and energy are generated. This process is known as “metabolism.”

Where and How Do We Normally Obtain Our Oxygen?
At each breath we fill our lungs with air containing 21% oxygen. Millions of tiny air sacs (known as “alveoli”) in our lungs inflate like tiny balloons. In the minutely thin walls enclosing each sac are microscopic capillaries, through which blood is constantly transporting oxygen from the lungs to every cell in the body. Because the body has no way to store oxygen, it leads a breath-to-breath existence.

How Much Oxygen Does the Human Body Need?
The rate of metabolism, which determines the need for and consumption of oxygen, depends on the degree of physical activity or mental stress of the individual. A person walking at a brisk pace will consume about four times as much oxygen as he or she would when sitting quietly. Under severe exertion or stress, he or she could be consuming eight times as much oxygen as when resting.

What Happens if the Body Does Not Receive Enough Oxygen?
When the body is deprived of an adequate oxygen supply, even for a short period, various organs and processes in the body begin to suffer impairment from oxygen deficiency. This condition is known as “hypoxia.” Hypoxia affects every cell in the body, but especially the brain and the body’s nervous system. This makes hypoxia extremely insidious, difficult to recognize, and a serious hazard especially for flight personnel.

What Are the Effects of Hypoxia?
Hypoxia causes impairment of vision (especially at night), lassitude, drowsiness, fatigue, headache, euphoria (a false sense of exhilaration), and temporary psychological disturbance. These effects do not necessarily occur in the same sequence nor to the same extent in all individuals, but are typical in average persons who are affeded by hypoxia.

When and Why Must We Use Extra Oxygen?
Supplementary oxygen must be used to enrich the air we breathe to compensate for either a deficiency on the part of the individual or a deficiency in the atmosphere in which we are breathing. A person may have a respiratory or circulatory impairment which reduces the ability of the body to utilize the 21% oxygen in the air. For such a person, supplementary oxygen must be administered by an oxygen tent or by oxygen mask to enrich the inhaled air. The total volume of oxygen in each inhalation is then so much greater than normal that it compensates for the individual’s own physical inability to utilize normal atmospheric oxygen. When we ascend in altitude, a different condition is encountered: a condition in which the individual may be perfectly normal, but in which there is an oxygen deficiency in the atmosphere and supplementary oxygen must therefore be used.

Does the Percentage of Oxygen in the Air Change with Altitude?
No, the ratio of oxygen to nitrogen in the composition of air does not change. The 21% of oxygen in the air remains relatively constant at altitudes up to one hundred thousand feet.

Why Must We Use Extra Oxygen When We Ascend in Altitude?
The blanket of air which surrounds our planet is several hundred miles thick, compressible, and has weight. The air closest to the earth is supporting the weight of the air above it and, therefore, is more dense; its molecules are packed closer together. As we ascend in altitude, the air is less dense. For example, at 10,000 feet, the atmospheric pressure is only two-thirds of that at ground level. Consequently, the air is less dense, and each lungful of air contains only two thirds as many molecules of oxygen as it did at ground level. At 18,000 feet the atmospheric pressure is only one-half of that at ground level. Although the percentage of oxygen is still the same as at ground level, the number of molecules of oxygen in each lungful is reduced by one-half. As we ascend, there is a progressive reduction in the amount of oxygen taken into the lungs with each breath, and a corresponding decrease in the amount of oxygen available for the bloodstream to pick up and transport to every cell in the body. To compensate for this progressive oxygen deficiency, we must add pure oxygen to the air we breathe in order to maintain enough oxygen molecules to supply the metabolic needs of the body.

At What Altitudes Should Oxygen Be Used?
In general, it can be assumed that the normal, healthy individual is unlikely to need supplementary oxygen at altitudes below 8,000 feet. One exception is night flying. Because the retina of the eye is affected by even extremely mild hypoxia, deterioration of night vision becomes significant above 5,000 feet. Between 8,000 and 12,000 feet, hypoxia may cause the first signs of fatigue, drowsiness, sluggishness, headache, and slower reaction time. At 15,000 feet, the hypoxic effect becomes increasingly apparent in terms of impaired efficiency, increased drowsiness, errors in judgment, and difficulty with simple tasks requiring mental alertness or muscular coordination. These symptoms become more intensified with progressively higher ascent or with prolonged exposure. At 20,000 feet, a pilot may scarcely be able to see, much less read, the instruments. His or her hearing, perception, judgment, comprehension, and general mental and physical faculties are practically useless. The pilot may be on the verge of complete collapse. Therefore, the availability and use of supplemental oxygen is recommended on night flights where altitudes above 5,000 feet are contemplated, and for altitudes above 8,000 feet on daytime flights.

How Can You Tell When You Need Oxygen?
You can’t; therefore, oxygen should be used before it is needed. The most dangerous aspect of hypoxia is the insidious, “sneaky” nature of its onset. Because the effects of hypoxia are primarily on the brain and nervous system, there is a gradual loss of mental faculties, impairment of judgment, coordination, and skill; but these changes are so slow that they are completely unnoticed by the individual who is being affected. Actually, a person suffering from mild or moderate hypoxia is apt to feel a sense of exhilaration or security, and may be quite proud of his or her proficiency and performance although he or she may be on the verge of complete incompetence. Because hypoxia acts upon the brain and nervous system, its effects are very much like those of alcohol or of other drugs which produce a false sense of well-being. There is a complete loss of ability for self-criticism or self-analysis. Some people believe that a pilot can detect his or her need for oxygen by noting an increase in breathing rate, an accelerated heartbeat, and a slight bluish discoloration (cyanosis) of the fingernails. However, by the time these symptoms develop, the individual is more likely to be mentally incapable of recognizing these signs. The person may even decide that he or she has always wanted blue fingernails! Even while “spiraling” out of control, the individual may be convinced (if conscious at all) that he or she is doing this deliberately and enjoying it immensely.

Are All Individuals Equally Affected by Hypoxia?
No, they are not. Just as there is a variation among individuals in their ability to tolerate heat, cold, or alcohol, some people can tolerate without apparent effect a degree of hypoxia which would have noticeable effects on others who are more susceptible to the lack of oxygen. There is no way to measure and predict hypoxia tolerance because it can be affected by physical con-dition, fatigue, emotion, tobacco, alcohol, drugs, diet and other factors. The individual who has flown at 14,000, 16,000, or 18,000 feet without oxygen and survived has no idea how close he or she may have been to disaster. The person may believe that all this talk about oxygen need, if true at all, does not apply to him or her. Such a belief may some day be fatal.

Is it True that Oxygen is Toxic or Harmful?
Oxygen therapy is often used for prolonged periods in hospitals and homes with beneficial effects. It is most generally agreed that a 60% oxygen concentration on the ground, which is equivalent to a 100% oxygen concentration at approximately 12,000 feet, will not cause any harmful effects.

Why Not Use Oxygen Intermittently for Short Periods?
If one is at an altitude where there is an oxygen deficiency, intermittent use of oxygen would only temporarily alleviate the hypoxic effects during the period in which oxygen is being used. Because of the insidious nature of hypoxia, a person already mildly hypoxic is very unlikely to even think of using oxygen equipment, either intermittently or otherwise. It is true that occasional use of oxygen for five or ten minutes (even at altitudes below 8,000 feet) can act as a “refresher” to relieve the effects of mild hypoxia, cigarette smoke, apprehension, or other factors. Also, the use of oxygen for five or ten minutes before the termination of a flight (even though the entire flight may have been flown at less than 8,000 feet) can be an excellent tonic to put the pilot in his or her best mental and physical condition for the approach procedures and landing maneuvers.

How Will Oxygen Equipment Improve the Utility of the Airplane?
With oxygen equipment aboard, the pilot can choose the higher altitudes which give the smoothest flight, the most favorable winds, the best performance from the Omni and other radio navigation equipment, the highest speed, the longest range, and the best engine performance. The pilot can have these advantages safely with oxygen because his or her own performance will not be affected by hypoxia; he or she will be just as efficient and capable as at lower altitudes or even on the ground. With oxygen equipment in use, pilot and passengers will arrive at their destination fresh and fit, without the headache, lassitude, and fatigue which often result from prolonged exposure to even mild hypoxia.

What Types of Oxygen Equipment Are Available for Private and Executive Aircraft?
There are a variety of types, including portable MH EDS “Pulse-Demand” units which can be carried along when flight at hypoxic altitudes is anticipated. If flights at such altitudes are frequent, then a “built-in” oxygen system offers some advantages, especially in the larger aircraft. For either portable or built-in systems there is a choice between “Pulse-Demand” type and “Continuous Flow” type equipment. “Pulse-Demand” type equipment automatically delivers oxygen to the user during each inhalation in response to his or her own breathing pattern and altitude. The continuous flow type system delivers oxygen at a fixed rate to an accumulator bag which is attached to the mask, and from which the user inhales each breath. The Pulse-Demand is the most efficient.

How Should an Oxygen System or Equipment Be Selected?
Your MH Sales Engineer can help you at 800-468-8185. He can assist the pilot in selecting the system best suited to the specific airplane and the pilot’s special needs.

WARNING:
Improper use or improper maintenance of aviation oxygen equipment may result in serious injury or death. Aviation oxygen equipment is intended to be used only for aviation applications and is to be used only by, or under the supervision of, a pilot or crew member trained and qualified in its use. Aviation oxygen equipment is to be serviced only in accordance with the applicable component maintenance manuals from MH Oxygen Systems and only be serviced by technicians trained in the inherent hazards of high pressure aviation oxygen and knowledgeable of this equipment. Aviation oxygen equipment is to be used only with oxygen meeting the requirements of MIL_PRF-27210

Features

  • Compact, lightweight, easy-to-use.
  • Automatically adjusts oxygen flow for pressure altitude.
  • Reduced oxygen consumption through more efficient oxygen delivery compared to constant-flow systems.
  • Rugged MIL-spec control switch for improved reliability. Positive position detents provide excellent tactile feedback and resistance to inadvertent changes.
  • Rotary mode-switch selects the EDS operating mode: Night, Delay or high-flow Facemask settings.
  • Large easy-to-grip indicator knob for ease of use and good visibility.
  • Red/Yellow/Green LEDs indicate oxygen flow status and alarm conditions.
  • Audible and visible FLOW-FAULT Alarm informs the user of kinked, pinched or disconnected oxygen lines.
  • Reduced dry mouth and sinus discomfort compared to constant-flow oxygen systems. 

About Mountain High Oxygen

Founded by pilot and engineer Patrick L. McLaughlin, Mountain High has been supplying aviation oxygen equipment and supplies since 1985. The company is known particularly for it’s EDS product, an electronic ‘Pulse-Demand™’ adaptive oxygen delivery device.

Mountain High has also been at the forefront of providing pilots of all types of aircraft with affordable and easy-to-use oxygen transfillers and adapters.


Write Your Own Review
You're reviewing:Mountain High EDS O2D1 or O2D2 Pulse Demand Kit